GREEN EX900 is chemical for boiler water treatment, which also contains neutralizing corrosion inhibitor for afterboiler section in one single composite formulation. The corrosion inhibitor contained in this chemical is TANNIC ACID, which is a safe substance compared with others such as hydrazine. Excellent dispersant is also contained, which effectively inhibits scale formation and disperses calcium or ferric oxide sludges.
<>
- Excellent corrosion inhibition inside the boiler
TANNIC ACID effectively inhibits corrosion inside the boiler by the following three functions:
- Oxygen removal
- Formation of insoluble films with iron
- Formation of passive films
- Excellent corrosion inhibition in the afterboiler section
NEUTRALIZING AMINES contained in this chemical effectively inhibits corrosion in the afterboiler section, by preventing the pH drop of condensate caused by carbon dioxide formed in the boiler.
- Excellent dispersion
The dispersant contained in this chemical effectively inhibits scale or deposit formation, which consequently prevents secondary corrosion occurring under the deposit.
- Energy is saved
As tannic acid do not produce any soluble solid, electric conductivity of boiler water do not increase like sodium sulfite. As a result, the blowdown rate is reduced, together with the amount of heat loss.
- Safety is improved
Safety of the chemical is improved, as TANNIC ACID is contained, which is a natural compound known as constituent of tea.
<>
Dose the chemical into the makeup to the dosage shown in the following table:
Dosage in the | Blowdown rate(%) |
makeup [mg/L] | ×10 |
Storage tanks made of stainless steel or synthetic resin such as polyvinyl chloride should be used.